SoftPlus Water Softeners Iron Rival Iron Reduction Systems ecoTAC Hard Water Conditioning Systems

Sterilight SPV-8 Ultraviolet (UV)
NSF-Certified Water Purifier

Sterilight SPV-8

The Sterilight SPV-8 has been replaced by the
Viqua PRO 10
which features:

Longer Warranty
Higher Flow Rate


- Click here for more info -
Sterilight SPV-8

This item has been discontinued by the manufacturer.
It has been replaced by the Viqua PRO 10, which offers a Longer Warranty and a Higher Flow Rate.

Sterilight Model SPV-8 Replacement Parts & Accessories

Sterilight S410RL-HO
Lamp

Sterilight S410RL-HO <br>Lamp

List Price: CDN$200.00
Our Price: CDN$170.00
You save: $30.00


- More Info -

Sterilight QS-410
Sleeve

Sterilight QS-410 <br>Sleeve

List Price: CDN$102.00
Our Price: CDN$87.00
You save: $15.00


- More Info -

The Sterilight SPV-8 NSF-certified UV water purifier is well suited for whole house disinfection for a small-sized home to kill bacteria (including coliform and e.coli), viruses, cryptosporidium, giardia, and a wide range of other microbiological contaminants where flow rates do not exceed 8.0 gallons per minute (30.3 LPM). It is loaded with features normally only found in expensive commercial systems including UV intensity monitor, flow restrictor, powered solenoid outputs, flow pacing, and multi-function digital display. It is an excellent choice for applications with a known bacteria or other microbiological contamination problem.

The Sterilight SPV-8 is based on the feature-laden Platinum™ ICE controller and Sterilight's Flow-Pace™ UV intensity monitor. This combination allows for 2-stage flow pacing where the lamps operate at half power when water is not flowing and full-power when the water is running. This allows the system to operate with minimal power requirements (excellent for applications powered by solar power systems!), at a lower operating cost, and with less heat build-up. The Platinum™ ICE controller provides constant output current and a universal power input (100-250V./50-60Hz.), as well as visually displaying % UV intensity, remaining lamp life, and total hours of operation. The system comes with a set of dry contacts allowing for the external hook-up of a remote device such as a solenoid valve (sold separately - see below), as well as a self-diagnostic check upon start-up, and an RJ-11 communications port. Using high-output, Sterilume™-HO coated low pressure germicidal UV lamps coupled with 304 stainless steel, axial flow sterilization chambers, the Platinum Series provides very high flow throughput capacity in a very compact system. The UV lamp provides a 4-log (99.99%) reduction of bacteria, viruses, and protozoan cysts (cryptosporidium and giardia) at the specified maximum flow rates. Lamp life is 9,000 hours (1 year).

The SPV-8 is NSF-certified (Class A, Standard 55).

Pre-treatment Requirements:

All UV sterilizers required sediment pre-filtration to reduce or eliminate the possibility that a targeted contaminant could "hide" behind a sediment particle in the "shadow" of the UV light and therefore not receive a full dose of UV light. Accordingly, the manufacturer strongly recommends sediment pre-filtration down to a level of 5 microns or smaller.

Water exceeding 120 ppm in hardness (7 grains per gallon) should be softened to reduce the risk that hard water mineral scale will build-up on the UV sleeve thereby reducing UV light distribution into the UV chamber. Similarly, iron levels exceeding 0.3 ppm or manganese levels exceeding 0.05 ppm should also be treated to prevent staining of the UV sleeve.

Elevated levels of certain other contaminants, such as tannins, can cause a reduction in UV transmittance (the ability of the water to transmit UV light). If the UV transmittance (UVT) of your water is less than 75% after the above-mentioned pre-treatment, activated carbon filtration may be desirable to improve UV transmittance. The majority of deep wells have a UVT of 85% or greater. If your UVT is unknown, select a model with a higher flow rate capacity then you feel you will really require (this will provide a higher UV dose at your desired flow rate), or add an activated carbon pre-filter to your system. We recommend the following pre-filter equipment:

Sterilight SPV-8 Specifications
Applications small house
Max. Flow Rate
(UV dose >40,000 μWs/cm2)*
8.0 GPM (30.3 LPG)
Water Chamber Material Electropolished 316 Stainless Steel
Chamber Length 26.0 inches / 66.0 cm
Chamber Diameter 3.5 inches / 8.9 cm
Controller Size 11 x 4.5 x 2 inches
(25.4 x 11.4 x 5.3 cm)
Lamp Sterilume-HO
Model S410RL-HO
Sleeve Quartz
Model QS-410
Electrical 100-240v, 50/60HZ
Power Consumption 52 watts
Lamp Power 45 watts
Inlet / Outlet Plumbing Ports Combo 3/4" FNPT, 1" MNPT
"Power-On" Indicator Light Has Feature
Audible Lamp Failure Alarm Has Feature
Lamp Replacement Reminder Has Feature
LED Display: Lamp Life Remaining, Total Controller Runtime, UV Intensity Has Feature
UV Intensity Monitor Has Feature
Powered Solenoid Output Has Feature
Flow Pacing Has Feature
Communications Port Has Feature
Diagnostic Check Has Feature
Flow Restrictor Has Feature
NSF-Certification Has Feature

*Note: Maximum recommended flow rates based on 95% UV transmittance. Actual dosage depends on flow rate, water quality, and maintenance (cleaning ov UV sleeve). UV dosage will be lower when the UV transmittance capacity of the water drops below 95% - if in doubt, select a model rated for a higher flow rate than you actually require. We recommend a UV dose of not less than 30,000 μWs/cm2.

Feed Water Quality Parameters
Iron 0.3 ppm
(0.3 mg/L)
Manganese 0.05 ppm
(0.05 mg/L)
Tannins 0.1 ppm
(0.1 mg/L)
Turbidity < 1 NTU
Hardness < 120 ppm
(7 grains / gallon)
UV Transmittance (UVT): > 75%
Maximum Temperature: 104F (40C)
Maximum Pressure: 125 psi