Sterilight SPV-950 Ultraviolet (UV)
NSF-Certified Water Purifier
Sterilight SPV-950 |
The Sterilight SPV-950 has been replaced by the Viqua PRO 20 which features: Longer Warranty Higher Flow Rate - Click here for more info - |
This item has been discontinued by the manufacturer.
It has been replaced by the Viqua PRO 20, which offers a Longer Warranty and a Higher Flow Rate.
Sterilight Model SPV-950 Replacement Parts & Accessories
The Sterilight SPV-950 NSF-certified UV water purifier is recommeded for larger homes and commercial applications to kill bacteria (including coliform and e.coli), viruses, cryptosporidium, giardia, and a wide range of other microbiological contaminants where flow rates do not exceed 14.9 gallons per minute (56.6 LPM). It is loaded with features normally only found in expensive commercial systems including UV intensity monitor, flow restrictor, powered solenoid outputs, flow pacing, and multi-function digital display. It is an excellent choice for applications with a known bacteria or other microbiological contamination problem.
The Sterilight SPV-950 is based on the feature-laden Platinum™ ICE controller and Sterilight's Flow-Pace™ UV intensity monitor. This combination allows for 2-stage flow pacing where the lamps operate at half power when water is not flowing and full-power when the water is running. This allows the system to operate with minimal power requirements (excellent for applications powered by solar power systems!), at a lower operating cost, and with less heat build-up. The Platinum™ ICE controller provides constant output current and a universal power input (100-250V/50-60Hz), as well as visually displaying % UV intensity, remaining lamp life, and total hours of operation. The system comes with a set of dry contacts allowing for the external hook-up of a remote device such as a solenoid valve (sold separately - see below), as well as a self-diagnostic check upon start-up, and an RJ-11 communications port. Using high-output, Sterilume™-HO coated low pressure germicidal UV lamps coupled with 304 stainless steel, axial flow sterilization chambers, the Platinum Series provides very high flow throughput capacity in a very compact system. The UV lamp provides a 4-log (99.99%) reduction of bacteria, viruses, and protozoan cysts (cryptosporidium and giardia) at the specified maximum flow rates. Lamp life is 9,000 hours (1 year).
The SPV-950 is NSF-certified (Class A, Standard 55).
Pre-treatment Requirements:
All UV sterilizers required sediment pre-filtration to reduce or eliminate the possibility that a targeted contaminant could "hide" behind a sediment particle in the "shadow" of the UV light and therefore not receive a full dose of UV light. Accordingly, the manufacturer strongly recommends sediment pre-filtration down to a level of 5 microns or smaller.
Water exceeding 120 ppm in hardness (7 grains per gallon) should be softened to reduce the risk that hard water mineral scale will build-up on the UV sleeve thereby reducing UV light distribution into the UV chamber. Similarly, iron levels exceeding 0.3 ppm or manganese levels exceeding 0.05 ppm should also be treated to prevent staining of the UV sleeve.
Elevated levels of certain other contaminants, such as tannins, can cause a reduction in UV transmittance (the ability of the water to transmit UV light). If the UV transmittance (UVT) of your water is less than 75% after the above-mentioned pre-treatment, activated carbon filtration may be desirable to improve UV transmittance. The majority of deep wells have a UVT of 85% or greater. If your UVT is unknown, select a model with a higher flow rate capacity then you feel you will really require (this will provide a higher UV dose at your desired flow rate), or add an activated carbon pre-filter to your system.
Optional Emergency Solenoid Shut-Off Kit:
The Sterilight SPV-950 can be equipped with an emergency solenoid shut-off kit. In the event of a power failure or electrical outage to your home, your UV lamp in your UV system will lose power. This could leave your home unprotected if someone turns on a water faucet. Some bacteria and other waterborne pathogens can also swim past an un-powered UV lamp and reach the downstream portion of your water system and therefore not receive a dose of UV light once the power is restored. The same situation could occur in the event of a UV bulb failure or in the event of a reduction in UV lamp output (drop in UV intensity below safe dosage level). The solenoid emergency shut-off valve is normally installed at the output of your UV system and will physically close a valve in the event of a bulb burn-out or power failure, thereby preventing any contaminant from passing through the system untreated. This feature will also turn off the water supply if there is a UV intensity loss (for models equipped with a UV intensity monitor). This kit is highly recommend for all homes with a known bacterial, virus, or cyst contamination problem, and for all homes with an electrical supply that is prone to frequent outages. Various valve sizes are available.
Sterilight SPV-950 Specifications | ||||||
---|---|---|---|---|---|---|
Applications | large homes commercial |
|||||
Max. Flow Rate (UV dose >40 mJ/cm2 at 75% UVT)* |
14.9 GPM (56 LPG) | |||||
Water Chamber Material | Electropolished 316 Stainless Steel | |||||
Chamber Length | 44.5 inches / 113.00 cm | |||||
Chamber Diameter | 3.5 inches / 8.9 cm | |||||
Controller Size | 10.75 x 4.5 x 2 inches (25.4 x 11.4 x 5.3 cm) |
|||||
Lamp | Sterilume-HO Model S950RL-HO |
|||||
Sleeve | Quartz Model QS-950 |
|||||
Electrical | 100-240v, 50/60HZ | |||||
Power Consumption | 110 watts | |||||
Lamp Power | 100 watts | |||||
Inlet / Outlet Plumbing Ports | Combo 3/4" FNPT, 1" MNPT | |||||
"Power-On" Indicator Light | ||||||
Audible Lamp Failure Alarm | ||||||
Lamp Replacement Reminder | ||||||
LED Display: Lamp Life Remaining, Total Controller Runtime, UV Intensity | ||||||
UV Intensity Monitor | ||||||
Powered Solenoid Output | ||||||
Flow Pacing | ||||||
Communications Port | ||||||
Diagnostic Check | ||||||
Flow Restrictor | ||||||
NSF-Certification | ||||||
Warranty | Reaction Chamber: 7 years
Lamp: 1 year All Other components:5 years |
*Note: Maximum recommended flow rates based on 75% UV transmittance. Actual dosage depends on flow rate, water quality, and maintenance (cleaning of UV sleeve). UV dosage will be lower when the UV transmittance capacity of the water drops below 75% and a UV intensity alarm will be triggered. We recommend a UV dose of not less than 40 mJ/cm2.
Feed Water Quality Parameters | |
---|---|
Iron | 0.3 ppm (0.3 mg/L) |
Manganese | 0.05 ppm (0.05 mg/L) |
Tannins | 0.1 ppm (0.1 mg/L) |
Turbidity | < 1 NTU |
Hardness | < 120 ppm (7 grains / gallon) |
UV Transmittance (UVT): | 75% |
Maximum Temperature: | 104F (40C) |
Maximum Pressure: | 125 psi |