Sterilight Silver Series Ultraviolet (UV) Sterilizers
The Sterilight Silver Series is ideally suited for point of use water treatment to kill bacteria (including coliform and e.coli), viruses, cryptosporidium, giardia, and a wide range of other microbiological contaminants. The larger Silver Series models, specifically the S5Q-PA, S8Q-PA, and S12Q-PA, can also be used for whole house applications where an economical unit with an average array of features is required. Given its economical price, the Silver Series is a popular choice for homeowners desiring protection against microbiological contaminants as a precautionary prophylactic treatment measure even though their water has not tested positive for bacteria or other pathogen.
Since the Silver Series cannot be equipped with a UV intensity monitor or emergency solenoid shut-off kit, homeowners with a known contamination problem with a serious contaminant like e.coli, cryptosporidium, or giardia, are generally recommended to select a Silver Plus Series or Platinum Series model for an even greater level of water safety (especially for whole house use).
All Silver Series units feature a stainless steel reactor chamber, a fire-polished domed quartz sleeve, and Sterilight Sterilume™-EX coated low pressure germicidal UV lamp which can be conveniently changed without interrupting the water flow. The UV lamp provides a 4-log (99.99%) reduction of bacteria, viruses, and protozoan cysts (cryptosporidium and giardia) at the specified maximum flow rates. The Silver Series electronic controller features a switchable power supply that automatically detects line voltage between 100-240 volt and adjusts its operating settings accordingly.
The Sterilight Silver Series is composed of six models with treatment capacities ranging from 1 to 15 gallons per minute.
- Sterilight SQ-PA
- Sterilight S1Q-PA
- Sterilight S2Q-PA
- Sterilight S5Q-PA
- Sterilight S8Q-PA
- Sterilight S12Q-PA
Sterilight SQ-PA |
Sterilight S1Q-PA |
Sterilight S2Q-PA |
Sterilight S5Q-PA |
Sterilight S8Q-PA |
Sterilight S12Q-PA |
|
---|---|---|---|---|---|---|
Applications | point-of-use |
point-of-use cabin |
average home | |||
Max. Flow Rate (UV dose >30 mJ/cm2)* |
1.5 GPM | 2 GPM (7 lpm) |
3 GPM (11 lpm) |
6 GPM (23 lpm) |
10 GPM (38 lpm) |
15 GPM (57 lpm) |
Max. Flow Rate (UV dose >40 mJ/cm2)* |
1 GPM | 1.5 GPM (5 lpm) |
2 GPM (7 lpm) |
4.5 GPM (17 lpm) |
8 GPM (29 lpm) |
11 GPM (42 lpm) |
Water Chamber Material | 304 Stainless Steel (316 stainless steel available by special order) | |||||
Chamber Length | 12.0 inches / 30.5 cm | 15.0 inches / 38.1 cm | 17.0 inches / 43.2 cm | 22.0 inches / 56.0 cm | 35.0 inches / 90.0 cm | 37.0 inches / 94.0 cm |
Chamber Diameter | 2.0 inches / 5.2 cm |
2.5 inches / 6.5 cm | 3.5 inches / 8.9 cm |
|||
Controller Size | 7.3 x 3.2 x 2.5 inches / (19.0 x 8.1 x 6.4 cm) | |||||
Lamp | Sterilume-EX Model S212RL |
Sterilume-EX Model S287RL |
Sterilume-EX Model S330RL |
Sterilume-EX Model S463RL |
Sterilume-EX Model S810RL |
Sterilume-EX Model S36RL |
Sleeve | Quartz Model QS-212 |
Quartz Model QS-001 |
Quartz Model QS-330 |
Quartz Model QS-463 |
Quartz Model QS-810 |
Quartz Model QS-012 |
Electrical | 100-240v, 50/60HZ (12V DC available by special order on SQ-PA, S1Q-PA, S2Q-PA & S5Q-PA) | |||||
Power Consumption | 15 watts | 19 watts | 22 watts | 30 watts | 46 watts | 48 watts |
Lamp Power | 10 watts | 14 watts | 17 watts | 24 watts | 37 watts | 39 watts |
Inlet / Outlet Plumbing Ports | 1/4" MNPT | 1/2" MNPT | 3/4" MNPT | Combo 3/4" FNPT / 1" MNPT | ||
"Power-On" Indicator Light | ||||||
Audible Lamp Failure Alarm | ||||||
Lamp Replacement Reminder | ||||||
LED Display: Lamp Life Remaining, Total Controller Runtime | ||||||
Recommended Flow Restrictors sold separately |
na | na | FR-02 or FRSS-2.5 |
FRSS-6-34 | FR-08 | FRSS-10, FRSS-12 or FRSS-15 |
Sterilight SQ-PA |
Sterilight S1Q-PA |
Sterilight S2Q-PA |
Sterilight S5Q-PA |
Sterilight S8Q-PA |
Sterilight S12Q-PA |
|
Price Switch to US pricing |
Discontinued
See UVMax Model A for replacement |
Discontinued
See Sterilight S2Q-PA for replacement |
Discontinued
See Viqua VH150 for replacement |
Discontinued
See Viqua VH200 for replacement |
Discontinued
See Viqua VH410 for replacement |
|
Sterilight SQ-PA | Sterilight S1Q-PA | Sterilight S2Q-PA | Sterilight S5Q-PA | Sterilight S8Q-PA | Sterilight S12Q-PA |
*Note: Maximum recommended flow rates based on 95% UV transmittance. Actual dosage depends on flow rate, water quality, and maintenance (cleaning of UV sleeve). UV dosage will be lower when the UV transmittance capacity of the water drops below 95% - if in doubt, select a model rated for a higher flow rate than you actually require. We recommend a UV dose of 40 mJ/cm2.
Feed Water Quality Parameters | |
---|---|
Iron | 0.3 ppm (0.3 mg/L) |
Manganese | 0.05 ppm (0.05 mg/L) |
Tannins | 0.1 ppm (0.1 mg/L) |
Turbidity | < 1 NTU |
Hardness | < 120 ppm (7 grains / gallon) |
UV Transmittance (UVT): | 75% |
Maximum Temperature: | 104F (40C) |
Maximum Pressure: | 125 psi |
Pre-treatment Requirements:
All UV sterilizers required sediment pre-filtration to reduce or eliminate the possibility that a targeted contaminant could "hide" behind a sediment particle in the "shadow" of the UV light and therefore not receive a full dose of UV light. Accordingly, the manufacturer strongly recommends sediment pre-filtration down to a level of 5 microns or smaller.
Water exceeding 120 ppm in hardness (7 grains per gallon) should be softened to reduce the risk that hard water mineral scale will build-up on the UV sleeve thereby reducing UV light distribution into the UV chamber. Similarly, iron levels exceeding 0.3 ppm or manganese levels exceeding 0.05 ppm should also be treated to prevent staining of the UV sleeve.
Elevated levels of certain other contaminants, such as tannins, can cause a reduction in UV transmittance (the ability of the water to transmit UV light). If the UV transmittance (UVT) of your water is less than 75% after the above-mentioned pre-treatment, activated carbon filtration may be desirable to improve UV transmittance. The majority of deep wells have a UVT of 85% or greater. If your UVT is unknown, select a model with a higher flow rate capacity then you feel you will really require (this will provide a higher UV dose at your desired flow rate), or add an activated carbon pre-filter to your system. We recommend the following pre-filter equipment:
WH1B+ 5 Micron Sediment Pre-Filter Package excellent overall sediment pre-treatment to 5 micron level |
WH2 Sediment & Activated Carbon Pre-Filter Package sediment pre-treatment to 5 microns and improves UV transmittance by removing tannins and other contaminants that reduce UVT |
WH5 Iron Reduction Filter Package very cost effective iron pre-treatment filter for iron levels ranging from 0.3 to 5.0 ppm |
Accessories:
The Sterilight Silver Series can be equipped with a flow restrictor to ensure that you do not exceed the maximum flow capacity of the system. We recommend that you choose a flow restrictor rated for slightly less flow than the UV sterilizer based on a UV dose of 40 mJ/cm2. For more details, review our flow restrictors page.