CAD / USD
CART
1-866-376-2690
SoftPlus Water Softeners Iron Rival Iron Reduction Systems ecoTAC Hard Water Conditioning Systems Black Friday Sale

Viqua (Trojan) UVMax Model J

Trojan UVMax Model J

The Trojan UVMax Model J has been replaced by the
Viqua UVMax H
which features:

Lower Price
Similar Flow Rate


- Click here for more info -
Trojan UVMax Model J

This item has been discontinued by the manufacturer.
It has been replaced by the Viqua UVMax H, which offers a Lower Price and a Similar Flow Rate.

UVMax Model J Replacement Parts & Accessories

Lamp & Sleeve Combo
Part#:602850-103

Lamp & Sleeve Combo <br>Part#:602850-103

List Price: CDN$594.00
Our Price: CDN$505.00
You save: $89.00


- More Info -

Replacement Lamp
Part#:602856

Replacement Lamp <br>Part#:602856

List Price: CDN$536.00
Our Price: CDN$456.00
You save: $80.00


- More Info -

Replacement Sleeve
Part#:602976

Replacement Sleeve <br>Part#:602976

List Price: CDN$136.00
Our Price: CDN$116.00
You save: $20.00


- More Info -

Solenoid Shut-off
Part#:650627

Solenoid Shut-off <br>Part#:650627

List Price: CDN$751.00
Our Price: CDN$638.00
You save: $113.00


- More Info -

Viqua 20 GPM
Flow Restrictor

Viqua 20 GPM <br>Flow Restrictor

List Price: CDN$150.00
Our Price: CDN$128.00
You save: $22.00


- More Info -

Replacement UVMax
CoolTouch Fan

Replacement UVMax <br>CoolTouch Fan

List Price: CDN$200.00
Our Price: CDN$119.00
You save: $81.00


- More Info -

UVMax Model J Replacement
Ballast (2009 to Present)

UVMax Model J Replacement<br>Ballast (2009 to Present)

List Price: CDN$1,850.00
Our Price: CDN$1,426.00
You save: $424.00


- More Info -

The Viqua (Trojan) UVMax Model J is the second largest model in Trojan's revolutionary new high output UVMax product line. The Model J offers convenient color-coded plug & play connections, innovative high-output lamps with 2 year service life, and a host of other performance and convenience features designed to make installation, operation, and maintenance as simple as possible. It can also be equiped with a wide range of optional equipment including a sophisticated UV intensity monitor with self diagnostic test (when equiped with the UV intensity monitor, this model is referred to as the Model J+), a solenoid emergency shut-off kit, and an inline flow restrictor. The Model H is well suited to large residential applications with low UVT, as well as commercial water treatment applications including bed and breakfast facilities, restaurants, rural resorts and lodges, etc., with flow rates up to 45 GPM.

The optional UV intensity monitor continuously monitors the intensity of the UV light to ensure that the water is receiving an adequate dose of UV light to kill the bacteria, viruses, etc. The use of a model with a UV intensity monitor is generally recommended where a known E.coli or other serious problem is present or the feed water parameters may cause problems with UV transmittance from time to time (sediment flushing, iron or hard water scale build-up on the UV sleeve etc.).

The CoolTouch fan system which is integrated into the Model G model, assists in system cooling during periods of inactive water use where conventional UV systems can often heat the water considerably as the water absorbs heat from the UV lamp. The CoolTouch fan thereby helps ensure maximum UV dose under all conditions as UV effectiveness decreases as the temperature declines.

The Viqua (Trojan) UVMax Model J can be equiped with an optional solenoid emergency shut-off kit. For more information on the emergency shut-off valve, CLICK HERE.

If the optional UV intensity monitor is selected, the Model J can also be equiped with Trojan's innovative new COMMCenter. The optional COMMCenter provides real-time dosage display so you an monitor the performance of your UV system. In addition to UV dose, the system displays alarm history, lamp hours, and other performance parameters. Moreover, the COMMCenter can be installed just about anywhere - simply connect the COMMCenter to the sterilizer using a standard computer cable. The COMMCenter can also be connected directly to your computer where you can use Trojan's MAXtrack software to obtain real-time dose data, track alarm and dose history, etc. for any given period of time. This data logging capability allows operators to demonstrate proper system operation to regulators and consumers, provides troubleshooting insights, and allows for proactive maintenance. These features make the COMMCenter an excellent choice for commercial applications where dosage reporting and logging is desirable to prove compliance with health regulations. It also accept standard mini-SD memory cards (same type used in many digital cameras) so you can download data and transfer to a computer so you can view and analyze the data in any standard spread sheet program. A single COMMCenter can monitor up to 9 UV systems simultaneously. The MAXtrack software can be downloaded from the manufacturer's website at no charge.

Viqua (Trojan) UVMax Model J Specifications
Application commercial
Maximum Flow Rate
(dose>40mJ/cm2)*
45 GPM
(170 LPM)**
Maximum Flow Rate
(dose>30mJ/cm2)*
45 GPM
(170 LPM)**
Audible/Visual Lamp
Failure Alarm
Has Feature
Alarm Reset Has Feature
Lamp Age Indicator Has Feature
Lamp Replacement
Reminder
Has Feature
Electropolished Exterior Has Feature
UV Intensity Monitor optional
Flow Restrictor optional
Color-Coded Plug & Play Connections Has Feature
CoolTouch Fan Has Feature
RJ55 Communications Ports Has Feature
2 Year Lamp Life Has Feature
NSF Certified?
(Standard 55 Class A)
no, see
Pro 30
Solenoid Emergency
Shut-off Valve Kit
optional
COMMCenter Monitoring Package optional if UV intensity monitor purchased
Water Chamber Material stainless
steel (316)
UV Sleeve Material quartz
Inlet/Oulet Combo 1 1/4 inch NPT, 1" FNPT
Electrical 120-240v, 50/60HZ
Total Power (watts) 230
Lamp Power (watts) 200
Chamber Assembly Size 41 x 4"
103 x 10cm
Control Module Size 13 x 6.5"
33 x 16.5 cm

* All flow rate recommendations are based on 95% UV transmittance (UVT) and after 9,000 hours of bulb operation. If your water has poor UVT, or if you are unsure of your UVT, select a model with a higher flow capacity than you would otherwise require.
** Inlet/outlet size restricts flow to 45 gpm.


Feed Water Quality Parameters
Iron 0.3 ppm
(0.3 mg/L)
Hardness 120 ppm
(7 grains / gallon)
UV Transmittance (UVT): 75%
Maximum Air Temperature: 104F (40C)
Minimum Air Temperature: 32F (0C)
Maximum Humidity: 100%
Maximum Pressure: 100 psi
Minimum Pressure: 10 psi